應急燈,澳洲標準的22.6.13:自容式應急燈不因短路,接地,中斷而受影響,這里的短路指的是什么短路?是電池短路?接地指的是什么?中斷指的是什么?要求通過22.12.7來驗證,是指分別在短路,接地,中斷 3個狀態(tài)下進行0.9倍電壓充電24小時后進行流明測試?用積分球還是分布式光度計?+ ~% \) r$ c# d8 u
22.6.13 The operation of a self-contained emergency luminaire in the emergency mode shall
not be influenced by a short-circuit, a contact to earth or an interruption, in the wiring of the
normal supply.6 [9 K8 p. l$ a; Q5 N# Q{: n
Compliance is checked by simulation of these supply wiring faults during the emergency mode6 W' K. Y3 T: w( {
cycle of the test given in 22.12.7. The luminaire shall function normally during the test./ L* u1 j% P+ X/ |9 G2 c0 R
- k2 x3 l@$ F
22.12.7 On completion of the thermal test (that is, having complete battery discharge
according to 22.12.4) a self-contained emergency luminaire shall be allowed to cool to its
rated ambient temperature (t
a
) or to 25 °C whichever is the higher and shall be subjected to a
24 h charging cycle at 0,9 times rated supply voltage after which the luminaire, with the lamp
as tested, shall operate satisfactorily in the emergency mode.provide the rated lumen output
at the end of the rated duration of operation.* ~# N. ^( R: h7 {- \# K# L